DIGI-44B Installation Guide
4. Confirm the Docklight communication settings (Docklight -
> Tools -> Project Settings) match the device. 9600/8/n/1
on the COM port named USB Serial Port (or COM 1 if using
your computer’s serial port instead of the adapter.
5. Start Communication.
6. Turn the power to the DIGI-44B on after 5 seconds, the
DIGI-44B will send some lines of information you can see in
the communications window. This confirms that you are
communicating properly.
7. In the “Send Sequences” window, press the Set IP Mode
DHCP button
8. Verify that the IP address changed in the
communication window. *Note it can take
5-10 seconds for the unit to report back the
confirmed change.